Case Studies
Treating a Sacral Metastatic Bone Lesion and Fracture
Your download will start automatically once you have provided the following information:
"Interventional radiology - in partner with Orthopedic, NSGY, Rad-Onc, Heme-Onc, Sports Medicine, and PM&R - can help provide image guided solutions to patients suffering from benign and malignant Lumbo-Sacral pathologies. Implant-based reconstruction thinking can move IR from spot-welding treatment with single agent cement to restoring biomechanics, enabling load bearing, and focusing on early mobilization."
- Provider
- Michael Clifton, M.D.
- Speciality
- Assistant Professor
- Facility
- University of Minnesota Medical School
- Bio
-
Medical School: American University of the Caribbean School of Medicine
Residency... More
Case Details
- Condition
- Pelvic Trauma
- Product(s)
-
iFuse TORQ TNT
- Patient
- 74-year-old female
Metastatic Cholangiocarcinoma Lesion in S1 with Associated Pathologic Sacral Fracture
Patient History: A 74-year-old female presented with metastatic cholangiocarcinoma and a 3.5cm metastatic lesion at S1. The lesion had an associated pathologic sacral fracture and encroached upon the S1 neuroforamen (Fig. 1).
- Patient's lesion, fracture, and radiculopathy required intervention.
- Sacral ala fracture associated with lesion identified on diagnostic imaging.
- Surgical plan involved radiofrequency ablation, transiliac-transsacral screw fixation to address the sacral fracture, and cementoplasty for additional reinforcement.
Surgical Treatment: RFA (Medtronic, Osteocool) was performed on the lesion in S1. A 150mm iFuse TORQ TNT implant was placed through the S1 corridor, followed by post-implantation cementoplasty around the TNT implant.
- Radiofrequency ablation was performed on the lesion at S1 (Fig. 2).
- A TNT 2.5mm diameter guide pin was placed in the cannula left by the Medtronic Kyphon 3.2mm K-wire.
- A 150mm iFuse TORQ TNT implant was inserted transiliac-transsacral in the S1 corridor, through the lesion space (Fig. 3).
- After the iFuse TORQ TNT implant was placed, cement applicators were used to insert 5 cc of cement into the metastatic lesion space* (Fig. 4).
*TNT is not indicated for cement augmentation
Healthcare professionals should refer to the Instructions For Use for indications, contraindications, warnings, and precautions at https://si-bone.com/label.
There are potential risks associated with iFuse procedures. They may not be appropriate for all patients and all patients may not benefit.
For information about the risks, visit https://si-bone.com/risks.
Fig 1
Fig 2
Fig 3
Fig 4